You can view the test results on the comparison pages and summary reports for beginners and professionals. You can go to the desired report or comparison/selection service through the menu on this page. Additionally, you can go to the comparison pages from any graph in this report and add other tested products for direct comparison.



This is a summary report of headphones for professionals.

You can additionally look for Phiaton MS 400






Sensitivity average in band from 100 Hz - 10 kHz122.5dB/V SPL
108.6dB/mW SPL
Impedance average in band from 40 Hz - 15 kHz40.6ohm
For 90 dB SPL, a voltage is required-32.5dBV
0.024VRMS
Taking into account the peak factor of 9 dB for the music signal-23.5 dBV
0.067VRMS
Measurements were performed on the stands:HDM-X, Human: romanrex


Frequency response Phiaton MS 400 headphone

АЧХ - Стенд: HDM-X

Your browser does not support Canvas
Graphics setting view
Channel

Range

Frequency band

Smoothing

АЧХ - Стенд: Human: romanrex

Your browser does not support Canvas
Graphics setting view
Channel

Range

Frequency band

Smoothing


Brief information

Clicking on the graph will take you to the comparison page of different models with advanced graph display settings.



Impedance / Electric phase Phiaton MS 400 headphone

Your browser does not support Canvas
Graphics setting view
Channel

Frequency band


Channel:LeftRight
Impedance average in band from 40 Hz - 15 kHz40.6 40.6ohm
Resistance at 1 kHz36.6 36.3ohm
Resistance at 500 Hz37.9 38.1ohm
The minimum value in band from 40 Hz - 15 kHz34.3 34.6ohm
The maximum value in band from 40 Hz - 15 kHz56.9 56.0ohm


Your browser does not support Canvas
Graphics setting view
Channel

Range

Frequency band


Channel:LeftRight
Phase deviation is the average in the range 40 Hz - 15 kHz-0.6 -0.6°
Phase at 1 kHz-5.9 -5.2°
Phase at 500 Hz-5.8 -5.9°
The minimum value in band from 40 Hz - 15 kHz-10.7 -10.1°
The maximum value in band from 40 Hz - 15 kHz17.2 17.3°



Brief information

Clicking on the graph will take you to the comparison page of different models with advanced graph display settings.



Frequency response and sensitivity Phiaton MS 400 headphone

Your browser does not support Canvas
Graphics setting view
Channel

Frequency band

Smoothing


Channel:LeftRight
Sensitivity average in band from 100 Hz - 10 kHz121.8 122.9dB/V SPL
Sensitivity average in band from 100 Hz - 10 kHz107.9109.0 dB/mW SPL
Sensitivity at 1 kHz124.6126.0dB/V SPL
Sensitivity at 500 Hz121.5123.1dB/V SPL


Your browser does not support Canvas
Graphics setting view
Type of chart

SPL


SPLVoltageCurrentPower
dB SPLdBVVRMSdB(mA)mAdBmmW
60-62.50.001-34.60.019-48.60.000
70-52.50.002-24.60.059-38.60.000
80-42.50.008-14.60.19-28.60.001
90-32.50.024-4.60.59-18.60.014
100-22.50.0755.41.9-8.60.14
110-12.50.2415.45.91.41.4
120-2.50.7525.418.511.414.0
1307.52.435.458.621.4140



Brief information

Clicking on the graph will take you to the comparison page of different models with advanced graph display settings.



Impulse response Phiaton MS 400 headphone

Your browser does not support Canvas
Graphics setting view
Channel

Stand

Duration for impulse

Waveforms


Your browser does not support Canvas
Graphics setting view
Channel

Stand

Frequency of square wave


Brief information

Clicking on the graph will take you to the comparison page of different models with advanced graph display settings.



 

Динамический спектр Phiaton MS 400 headphone

Ваттерфол

Your browser does not support Canvas
Graphics setting view
Channel

Stand

Frequency band

Graph Display Type

Затухание

Your browser does not support Canvas
Graphics setting view
Channel

Stand

Frequency band

Graph Display Type


Brief information

Clicking on the graph will take you to the comparison page of different models with advanced graph display settings.



Other summary reports for Phiaton MS 400 headphone

report for a newbie

Your browser does not support CanvasA simple report for beginners with explanations of the main characteristics.

Compatibility with amplifier sources

Your browser does not support CanvasA report evaluating the compatibility of Phiaton MS 400 with various amplifier sources.

Target curves and equalization

Your browser does not support CanvasA report with an assessment of compliance with target curves and recommended settings for Phiaton MS 400 equalization



More detailed

Measurements of Phiaton MS 400 were carried out by Roman Kuznetsov on the hardware-software complex RAA.

The Phiaton MS 400 test was conducted as a black box test, without regard to cost and prestige. This is the basic principle for making measurements, measurement reports and developing tests in RAA.

I believe that it is important to do not make an absolute assessment of the device, but an aggregate assessment when working together with a source amplifier and taking into account external factors. This allows you to effectively reveal the potential of the entire set of devices or to make a more optimal choice of components.




Kuznetsov Roman
Founder of RAA



Known by the nickname romanrex
Аuthor of articles iXBT.com



Information for Authors. You can freely use the graphics in your articles with a link to us.












Original text in Russian page. Translation page is not yet ready

You can help with translation via the: facebook and feedback.




Comments

No comments to Phiaton MS 400
Commentary view:





Want to leave a comment or ask a question? Register now or log in