Measurement's report Sony CD3000 test and graphs - Reference Audio Analyzer

Sony CD3000 is available in reports and services. You are in a professional report.

Service and suite of tests

Information for all

Comparison of on-line graphs


Reports / Sony / CD3000 / report for a pro

Conducted technical work on updating the report. Charts may temporarily not be displayed at the time of the work.

Sony CD3000 (report for a pro)



Test report - general data of Sony CD3000 headphone

Frequency response, Impedance, Frequency response with standard AMPs


Graphics setting view
Stands:
Range, dB:

Perception of headphone frequency response curves of equal loudness ISO 226-2009


General results
General results Sony CD3000
Channel
Center/Summary
Sensitivity average in band from 100 Hz to 10 kHz, dB/V
110,0
Impedance average in band from 40 Hz to 15 kHz, ohm
40,6
For 94,0 dB SPL need, VRMS
0,158
For 94,0 dB SPL need, mW
0,612

The table shows a most important technical characteristics of Sony CD3000

*Center channel headphone is received by averaging between left and right channels



Test conditions
  • Type of headphones: Over-ear
  • Measurements were performed on the stands:
    • with on the simulator of human head with ears HDM1
    • with soft flat stand SF1
  • Table's data are based on the results from the test stand HDM1



Sensitivity of Sony CD3000 headphone


Graphics setting view
Stands:
Channel:




Table of measured characteristics
Sensitivity Sony CD3000
Channel
Left
Right
Sensitivity average in band from 100 Hz to 10 kHz, dB/V
110,1
110,0
Sensitivity at 500 Hz at 1 V, dB
112,4
113,6
Sensitivity at 500 Hz at 1 mW, dB
94,0
94,3
Sensitivity at 1000 Hz at 1 V, dB
114,6
115,1
Sensitivity at 1000 Hz at 1 mW, dB
97,9
97,6

The sensitivity was calculated by data from the measuring stand HDM1


Frequency response of Sony CD3000 headphone


Graphics setting view
Stands:
Range, dB:
Channel:




Table of measured characteristics
Frequency response Sony CD3000
Channel
Left
Right
Variation in frequency response in band from 100 Hz to 10 kHz, dB
-5,08, 4,79
-5,72, 5,39


The RMS variation between the right and left channels
Sony CD3000 from stand SF1
Deviation between channels in band 40 Hz to 15 kHz, dB
0,5
Deviation between channels in low-frequency range 40 Hz to 200Гц, дБ
0,3
Deviation between channels in mid-frequency range 200 Hz to 2 kHz, dB
0,3
Deviation between channels in hi-frequency range 2 kHz 15 kHz, dB
0,6

Impedance of Sony CD3000 headphone


Graphics setting view
Channel:




Table of measured characteristics
Impedance Sony CD3000
Channel
Left
Right
Impedance average in band from 40 Hz to 15 kHz, ohm
40,6
40,7
Resistance at 500 Hz, ohm
39,4
40,0
Resistance at 1000 Hz, ohm
37,9
38,7
The minimum value in band from 40 Hz to 15 kHz at frequency, Hz
9093,4
9241,5
The minimum value in band from 40 Hz to 15 kHz, ohm
37,5
38,1
The maximum value in band from 40 Hz to 15 kHz at frequency, Hz
62,6
83,7
The maximum value in band from 40 Hz to 15 kHz, ohm
45,7
45,3

Electric phase of Sony CD3000 headphone


Graphics setting view
Range, degree:
Channel:




Table of measured characteristics
Electric phase Sony CD3000
Channel
Left
Right
Average variation in phase response in band from 20 Hz to 20 kHz, degree
1,2
1,4
The minimum value in band from 20 Hz to 20 kHz at frequency, Hz
300,2
315,1
The minimum value in band from 20 Hz to 20 kHz, degree
-5,8
-3,9
The maximum value in band from 20 Hz to 20 kHz at frequency, Hz
19756,5
19756,5
The maximum value in band from 20 Hz to 20 kHz, degree
10,8
10,2

Frequency response of Sony CD3000 headphone when connected to amplifiers with constant output impedance


Graphics setting view
Stands:
Range, dB:
Channel:




Table of measured characteristics
Frequency response of headphone Sony CD3000 with amplifier with a constant impedance
Channel
Left
Right
Variation in FR from AMP 0 ohm in band 100 Hz to 10 kHz, dB
-2,84, +6,05
-4,43, +3,82
Variation in FR from AMP 10 ohm in band 100 Hz to 10 kHz, dB
-2,90, +5,96
-4,47, +3,74
Variation in FR from AMP 20 ohm in band 100 Hz to 10 kHz, dB
-2,94, +5,90
-4,51, +3,68
Variation in FR from AMP 50 ohm in band 100 Hz to 10 kHz, dB
-3,00, +5,80
-4,56, +3,60
Variation in FR from AMP 100 ohm in band 100 Hz to 10 kHz, dB
-3,04, +5,72
-4,60, +3,53
Variation in FR from AMP 300 ohm in band 100 Hz to 10 kHz, dB
-3,09, +5,65
-4,64, +3,47

Deviation of frequency response of Sony CD3000 headphone when connected to amplifiers with constant output impedance


Graphics setting view
Stands:
Range, dB:
Channel:




Table of measured characteristics
Variation in frequency response with amplifiers with constant output resistance from Sony CD3000
Channel
Center/Summary
With amplifier impedance at 10 ohm in band 20 Hz to 20 kHz, dB
0,3
With amplifier impedance at 20 ohm in band 20 Hz to 20 kHz, dB
0,5
With amplifier impedance at 50 ohm in band 20 Hz to 20 kHz, dB
0,9
With amplifier impedance at 100 ohm in band 20 Hz to 20 kHz, dB
1,1
With amplifier impedance at 300 ohm in band 20 Hz to 20 kHz, dB
1,4

*Center channel is received by data averaging between the left and right channels


Frequency response of Sony CD3000 headphone when connected to an amplifier with zero output impedance and raising of output impedanse in low frequencies


Graphics setting view
Stands:
Range, dB:
Channel:




Table of measured characteristics
Frequency response with an amplifier with zero output resistance and raising of output resistance in low frequencies from Sony CD3000
Channel
Left
Right
Variation in frequency response in band from 100 Hz to 10 kHz, dB
-5,10, 4,85
-5,73, 5,10

Deviation of frequency response of Sony CD3000 headphone when connected to an amplifier with zero output impedance and raising of output impedanse in low frequencies


Graphics setting view
Stands:
Range, dB:
Channel:




Table of measured characteristics
Variance of frequency response Sony CD3000 depending on the total output resistance of the amplifier with zero resistance and a rise of resistance at low frequencies
Variance frequency response at the frequency 20 Hz, dB
-4,4
Variance frequency response at the frequency 20 Hz, dB
-4,4
Variance frequency response at the frequency 40 Hz, dB
-1,7
Variance frequency response at the frequency 40 Hz, dB
-1,7
Variance frequency response at the frequency 80 Hz, dB
-0,6
Variance frequency response at the frequency 80 Hz, dB
-0,6

Perception of headphone frequency response curves of equal loudness ISO 226-2009 of Sony CD3000 headphone


Graphics setting view
Stands:
Channel:




Table of measured characteristics
Perception of headphone frequency response curves of equal loudness ISO 226-2009 from Sony CD3000
Channel
Center/Summary
From level 48 dB at 72 dB SPL in band 100 Hz to 10 kHz, dB
-8,0, +13,0
From level 36 dB at 72 dB SPL in band 100 Hz to 10 kHz, dB
-6,9, +10,0
From level 24 dB at 72 dB SPL in band 100 Hz to 10 kHz, dB
-5,8, +6,9
From level 12 dB at 72 dB SPL in band 100 Hz to 10 kHz, dB
-4,7, +5,0
From level 0 dB at 72 dB SPL in band 100 Hz to 10 kHz, dB
-3,6, +4,8
From level -12 dB at 72 dB SPL in band 100 Hz to 10 kHz, dB
-3,1, +4,7
From level -24 dB at 72 dB SPL in band 100 Hz to 10 kHz, dB
-5,1, +4,8
From level -36 dB at 72 dB SPL in band 100 Hz to 10 kHz, dB
-7,8, +5,7

*Center channel is received by data averaging between the left and right channels

Table's data are based on the results from the test stand HDM1



On-line comparison and selection services for Sony CD3000

Comparison the frequency response.
The Sony CD3000 was tested for a long time at the stands of the last generation and does not participate in comparison. If possible, we will re-test the Sony CD3000 on modern stands.
Compare the frequency response of a bundle of headphones and amplifiers.
The Sony CD3000 was tested for a long time at the stands of the last generation and does not participate in comparison. If possible, we will re-test the Sony CD3000 on modern stands.

Compare the sensitivity and impedance Sony CD3000 versus other models.

The automatic selection of the optimal AMP models from Sony CD3000 from the measured power parameters of the amplifying part and the measured parameters of the headphones for different purpose of use.

Сравнение АЧХ и звукового давления Sony CD3000 в зависимости от подаваемого напряжения и импеданса усилителя.


Измерения Sony CD3000 проведены Романом Кузнецовым на программно-аппаратном комплексе RAA.

Тест Sony CD3000 проведен как черного ящика, без учета стоимости и престижа. Это главный принцип измерений и разработки тестов в RAA.



Kuznetsov Roman
Founder of RAA



Known by the nickname romanrex
Аuthor of articles iXBT.com



Original text in Russian page. Translation page is not yet ready

You can help with translation via the: forum, facebook and feedback.


Share

If you notice a typo or other inaccuracy, then select it and press Ctrl+Enter. This will accelerate the process of improving the reports.

The original language of the report in Russian. If the text in the report is unclear, use online translators Russian-language report (and help with the correct translation into English)

Glossary: RUS, ENG. To display on page ID need to enable debug mode.

Debug mode: Switch ON





Follow