Snorry SI-2 Measurement's report - Reference Audio Analyzer

Reports / Snorry / SI-2 - report for a pro

Snorry SI-2 (report for a pro)

After testing in the benchmark mode in the Reference Audio Analyzer software, the data is added to the online database of the RAA website.

You can view the test results on the comparison pages and summary reports for beginners and professionals. You can go to the desired report or comparison/selection service through the menu on this page. Additionally, you can go to the comparison pages from any graph in this report and add other tested products for direct comparison.



This is a summary report of headphones for professionals.

You can additionally look for Snorry SI-2






Sensitivity average in band from 100 Hz - 10 kHz104.0dB/V SPL
89.6dB/mW SPL
Impedance average in band from 40 Hz - 15 kHz36.6ohm
For 90 dB SPL, a voltage is required-14.0dBV
0.200VRMS
Taking into account the peak factor of 9 dB for the music signal-5.0 dBV
0.564VRMS
Measurements were performed on the stands:HDM-X, Human: romanrex


Frequency response Snorry SI-2 headphone

АЧХ - Стенд: HDM-X

Your browser does not support Canvas
Graphics setting view
Channel

Range

Frequency band

Smoothing

АЧХ - Стенд: Human: romanrex

Your browser does not support Canvas
Graphics setting view
Channel

Range

Frequency band

Smoothing


Brief information

Clicking on the graph will take you to the comparison page of different models with advanced graph display settings.



Impedance / Electric phase Snorry SI-2 headphone

Your browser does not support Canvas
Graphics setting view
Channel

Frequency band


Channel:LeftRight
Impedance average in band from 40 Hz - 15 kHz36.2 36.9ohm
Resistance at 1 kHz36.2 37.0ohm
Resistance at 500 Hz36.3 37.0ohm
The minimum value in band from 40 Hz - 15 kHz36.2 36.9ohm
The maximum value in band from 40 Hz - 15 kHz36.3 37.1ohm


Your browser does not support Canvas
Graphics setting view
Channel

Range

Frequency band


Channel:LeftRight
Phase deviation is the average in the range 40 Hz - 15 kHz0.2 0.2°
Phase at 1 kHz0.1 0.1°
Phase at 500 Hz0.1 0.1°
The minimum value in band from 40 Hz - 15 kHz-0.0 -0.0°
The maximum value in band from 40 Hz - 15 kHz1.3 1.2°



Brief information

Clicking on the graph will take you to the comparison page of different models with advanced graph display settings.



Frequency response and sensitivity Snorry SI-2 headphone

Your browser does not support Canvas
Graphics setting view
Channel

Frequency band

Smoothing


Channel:LeftRight
Sensitivity average in band from 100 Hz - 10 kHz103.8 104.1dB/V SPL
Sensitivity average in band from 100 Hz - 10 kHz89.489.8 dB/mW SPL
Sensitivity at 1 kHz106.2106.0dB/V SPL
Sensitivity at 500 Hz106.0105.3dB/V SPL


Your browser does not support Canvas
Graphics setting view
Type of chart

SPL


SPLVoltageCurrentPower
dB SPLdBVVRMSdB(mA)mAdBmmW
60-44.00.006-15.20.17-29.60.001
70-34.00.020-5.20.55-19.60.011
80-24.00.0634.81.7-9.60.11
90-14.00.2014.85.50.391.1
100-4.00.6324.817.310.410.9
1106.02.034.854.720.4109
12016.06.344.817330.41093
13026.020.054.854740.410928



Brief information

Clicking on the graph will take you to the comparison page of different models with advanced graph display settings.



Impulse response Snorry SI-2 headphone

Your browser does not support Canvas
Graphics setting view
Channel

Stand

Duration for impulse

Waveforms


Your browser does not support Canvas
Graphics setting view
Channel

Stand

Frequency of square wave


Brief information

Clicking on the graph will take you to the comparison page of different models with advanced graph display settings.



 

Динамический спектр Snorry SI-2 headphone

Ваттерфол

Your browser does not support Canvas
Graphics setting view
Channel

Stand

Frequency band

Graph Display Type

Затухание

Your browser does not support Canvas
Graphics setting view
Channel

Stand

Frequency band

Graph Display Type


Brief information

Clicking on the graph will take you to the comparison page of different models with advanced graph display settings.



Other summary reports for Snorry SI-2 headphone

report for a newbie

Your browser does not support CanvasA simple report for beginners with explanations of the main characteristics.

Compatibility with amplifier sources

Your browser does not support CanvasA report evaluating the compatibility of Snorry SI-2 with various amplifier sources.

Target curves and equalization

Your browser does not support CanvasA report with an assessment of compliance with target curves and recommended settings for Snorry SI-2 equalization



More detailed

Measurements of Snorry SI-2 were carried out by Roman Kuznetsov on the hardware-software complex RAA.

The Snorry SI-2 test was conducted as a black box test, without regard to cost and prestige. This is the basic principle for making measurements, measurement reports and developing tests in RAA.

I believe that it is important to do not make an absolute assessment of the device, but an aggregate assessment when working together with a source amplifier and taking into account external factors. This allows you to effectively reveal the potential of the entire set of devices or to make a more optimal choice of components.




Kuznetsov Roman
Founder of RAA



Known by the nickname romanrex
Аuthor of articles iXBT.com



Information for Authors. You can freely use the graphics in your articles with a link to us.




Snorry SI-2 is available in reports and services. You are in a professional report.

Information for entry level users


Information for professionals









Original text in Russian page. Translation page is not yet ready

You can help with translation via the: facebook and feedback.