You can view the test results on the comparison pages and summary reports for beginners and professionals. You can go to the desired report or comparison/selection service through the menu on this page. Additionally, you can go to the comparison pages from any graph in this report and add other tested products for direct comparison.



This is a summary report of headphones for professionals.

You can additionally look for Sivga Audio Luan






Sensitivity average in band from 100 Hz - 10 kHz116.8dB/V SPL
103.4dB/mW SPL
Impedance average in band from 40 Hz - 15 kHz45.8ohm
For 90 dB SPL, a voltage is required-26.8dBV
0.046VRMS
Taking into account the peak factor of 9 dB for the music signal-17.8 dBV
0.129VRMS
Measurements were performed on the stands:HDM-X, Human: romanrex


С 2024 года измерения полноразмерных наушников в RAA проводятся не только на инструментальных стендах, но и вживую с помощью разработанной системы в RAA - Live Measurement System. Это позволяет увидеть реальное поведение наушников и их вариативность звучания относительно стандартных стендов. Результаты таких измерений в отчетах обозначаются как со стендов Human. В этом отчете - это: Human: romanrex

Т.к. АЧХ зависит от посадки наушников и их прогрева/износа, то в RAA была разработан универсальный комплект Live Measurement System для контроля своих наушников на собственной голове. Типовые комплекты доступны для приобретения.


Frequency response Sivga Audio Luan headphone

АЧХ - Стенд: HDM-X

Your browser does not support Canvas
Graphics setting view
Channel

Range

Frequency band

Smoothing

АЧХ - Стенд: Human: romanrex

Your browser does not support Canvas
Graphics setting view
Channel

Range

Frequency band

Smoothing


Brief information

Clicking on the graph will take you to the comparison page of different models with advanced graph display settings.



Impedance / Electric phase Sivga Audio Luan headphone

Your browser does not support Canvas
Graphics setting view
Channel

Frequency band


Channel:LeftRight
Impedance average in band from 40 Hz - 15 kHz46.0 45.5ohm
Resistance at 1 kHz44.2 43.6ohm
Resistance at 500 Hz44.3 43.8ohm
The minimum value in band from 40 Hz - 15 kHz41.5 40.9ohm
The maximum value in band from 40 Hz - 15 kHz60.6 60.6ohm


Your browser does not support Canvas
Graphics setting view
Channel

Range

Frequency band


Channel:LeftRight
Phase deviation is the average in the range 40 Hz - 15 kHz-0.8 -0.7°
Phase at 1 kHz-0.3 -0.5°
Phase at 500 Hz-1.6 -1.7°
The minimum value in band from 40 Hz - 15 kHz-7.4 -7.5°
The maximum value in band from 40 Hz - 15 kHz10.1 11.8°



Brief information

Clicking on the graph will take you to the comparison page of different models with advanced graph display settings.



Frequency response and sensitivity Sivga Audio Luan headphone

Your browser does not support Canvas
Graphics setting view
Channel

Frequency band

Smoothing


Channel:LeftRight
Sensitivity average in band from 100 Hz - 10 kHz116.0 117.5dB/V SPL
Sensitivity average in band from 100 Hz - 10 kHz102.6104.0 dB/mW SPL
Sensitivity at 1 kHz112.1114.0dB/V SPL
Sensitivity at 500 Hz115.9116.8dB/V SPL


Your browser does not support Canvas
Graphics setting view
Type of chart

SPL


SPLVoltageCurrentPower
dB SPLdBVVRMSdB(mA)mAdBmmW
60-56.80.001-30.00.032-43.40.000
70-46.80.005-20.00.10-33.40.000
80-36.80.015-10.00.32-23.40.005
90-26.80.0460.0231.0-13.40.046
100-16.80.1510.03.2-3.40.46
110-6.80.4620.010.06.64.6
1203.21.530.031.716.646.0
13013.24.640.010026.6460



Brief information

Clicking on the graph will take you to the comparison page of different models with advanced graph display settings.



Impulse response Sivga Audio Luan headphone

Your browser does not support Canvas
Graphics setting view
Channel

Stand

Duration for impulse

Waveforms


Your browser does not support Canvas
Graphics setting view
Channel

Stand

Frequency of square wave


Brief information

Clicking on the graph will take you to the comparison page of different models with advanced graph display settings.



 

Динамический спектр Sivga Audio Luan headphone

Ваттерфол

Your browser does not support Canvas
Graphics setting view
Channel

Stand

Frequency band

Graph Display Type

Затухание

Your browser does not support Canvas
Graphics setting view
Channel

Stand

Frequency band

Graph Display Type


Brief information

Clicking on the graph will take you to the comparison page of different models with advanced graph display settings.



Other summary reports for Sivga Audio Luan headphone

report for a newbie

Your browser does not support CanvasA simple report for beginners with explanations of the main characteristics.

Compatibility with amplifier sources

Your browser does not support CanvasA report evaluating the compatibility of Sivga Audio Luan with various amplifier sources.

Target curves and equalization

Your browser does not support CanvasA report with an assessment of compliance with target curves and recommended settings for Sivga Audio Luan equalization



More detailed

Measurements of Sivga Audio Luan were carried out by Roman Kuznetsov on the hardware-software complex RAA.

The Sivga Audio Luan test was conducted as a black box test, without regard to cost and prestige. This is the basic principle for making measurements, measurement reports and developing tests in RAA.

I believe that it is important to do not make an absolute assessment of the device, but an aggregate assessment when working together with a source amplifier and taking into account external factors. This allows you to effectively reveal the potential of the entire set of devices or to make a more optimal choice of components.




Kuznetsov Roman
Founder of RAA



Known by the nickname romanrex
Аuthor of articles iXBT.com



Information for Authors. You can freely use the graphics in your articles with a link to us.












Original text in Russian page. Translation page is not yet ready

You can help with translation via the: facebook and feedback.




Comments

Commentary view:





Комментарий из чата telegram RAA от Олег Дуюнов
Изображения, медиа и смайлы доступны в исходном чате.
2024-12-26 17:56:00

Комментарий к профессиональному отчету Sivga Audio Luan
Добрый день всем. Хотел спросить, столкнулся с распространённой проблемой SIVGA luan (клятая трещина на чашке). Насколько сильно это повлияет на что либо кроме внешней эстетики?
Просто думаю сдавать на замену (при учете что не факт что новые не треснуть так же) или заделать эти эпоксидной. Очень уж зашли они мне
Reply Edit


Комментарий из чата telegram RAA от GN
Изображения, медиа и смайлы доступны в исходном чате.
2024-12-26 18:54:56

Комментарий к профессиональному отчету Sivga Audio Luan
Можно заклеить аккуратно. Но если я правильно понимаю, там проблема не в клее, а в том, что дерево плохо обработано и само плохого качества и материал ведет. То есть лучше сдавать. Клей не факт, что поможет надолго.
Reply Edit


Want to leave a comment or ask a question? Register now or log in