Philips SHB 9100 (report for a pro)



Test report - general data of Philips SHB 9100 headphone

Frequency response, Impedance, Frequency response with standard AMPs


Graphics setting view
Stands:
Range, dB:

Perception of headphone frequency response curves of equal loudness ISO 226-2009


General results
General results Philips SHB 9100
Channel
Center/Summary
Sensitivity average in band from 100 Hz to 10 kHz, dB/V
113,1
Impedance average in band from 40 Hz to 15 kHz, ohm
34,6
For 94,0 dB SPL need, VRMS
0,111
For 94,0 dB SPL need, mW
0,353

The table shows a most important technical characteristics of Philips SHB 9100

*Center channel headphone is received by averaging between left and right channels



Test conditions
  • Type of headphones: On-ear
  • Measurements were performed on the stands:
    • with on the simulator of human head with ears HDM1
    • with soft flat stand SF1
  • Table's data are based on the results from the test stand HDM1



Sensitivity of Philips SHB 9100 headphone


Graphics setting view
Stands:
Channel:




Table of measured characteristics
Sensitivity Philips SHB 9100
Channel
Left
Right
Sensitivity average in band from 100 Hz to 10 kHz, dB/V
112,9
113,4
Sensitivity at 500 Hz at 1 V, dB
110,9
111,6
Sensitivity at 500 Hz at 1 mW, dB
97,7
97,2
Sensitivity at 1000 Hz at 1 V, dB
112,2
112,8
Sensitivity at 1000 Hz at 1 mW, dB
94,2
95,4

The sensitivity was calculated by data from the measuring stand HDM1


Frequency response of Philips SHB 9100 headphone


Graphics setting view
Stands:
Range, dB:
Channel:




Table of measured characteristics
Frequency response Philips SHB 9100
Channel
Left
Right
Variation in frequency response in band from 100 Hz to 10 kHz, dB
-4,71, 7,27
-4,15, 6,10


The RMS variation between the right and left channels
Philips SHB 9100 from stand SF1
Deviation between channels in band 40 Hz to 15 kHz, dB
0,5
Deviation between channels in low-frequency range 40 Hz to 200Гц, дБ
0,2
Deviation between channels in mid-frequency range 200 Hz to 2 kHz, dB
0,6
Deviation between channels in hi-frequency range 2 kHz 15 kHz, dB
0,6

Impedance of Philips SHB 9100 headphone


Graphics setting view
Channel:




Table of measured characteristics
Impedance Philips SHB 9100
Channel
Left
Right
Impedance average in band from 40 Hz to 15 kHz, ohm
35,0
34,3
Resistance at 500 Hz, ohm
34,1
33,5
Resistance at 1000 Hz, ohm
34,2
33,5
The minimum value in band from 40 Hz to 15 kHz at frequency, Hz
589,7
649,1
The minimum value in band from 40 Hz to 15 kHz, ohm
34,1
33,5
The maximum value in band from 40 Hz to 15 kHz at frequency, Hz
14990,4
14990,4
The maximum value in band from 40 Hz to 15 kHz, ohm
37,1
36,5

Electric phase of Philips SHB 9100 headphone


Graphics setting view
Range, degree:
Channel:




Table of measured characteristics
Electric phase Philips SHB 9100
Channel
Left
Right
Average variation in phase response in band from 20 Hz to 20 kHz, degree
3,2
3,4
The minimum value in band from 20 Hz to 20 kHz at frequency, Hz
99,6
98,1
The minimum value in band from 20 Hz to 20 kHz, degree
-1,9
-1,2
The maximum value in band from 20 Hz to 20 kHz at frequency, Hz
19682,2
19682,2
The maximum value in band from 20 Hz to 20 kHz, degree
21,1
21,4

Frequency response of Philips SHB 9100 headphone when connected to amplifiers with constant output impedance


Graphics setting view
Stands:
Range, dB:
Channel:




Table of measured characteristics
Frequency response of headphone Philips SHB 9100 with amplifier with a constant impedance
Channel
Left
Right
Variation in FR from AMP 0 ohm in band 100 Hz to 10 kHz, dB
-2,89, +4,31
-2,99, +5,25
Variation in FR from AMP 10 ohm in band 100 Hz to 10 kHz, dB
-2,92, +4,40
-2,94, +5,26
Variation in FR from AMP 20 ohm in band 100 Hz to 10 kHz, dB
-2,94, +4,46
-2,90, +5,27
Variation in FR from AMP 50 ohm in band 100 Hz to 10 kHz, dB
-2,97, +4,56
-2,85, +5,29
Variation in FR from AMP 100 ohm in band 100 Hz to 10 kHz, dB
-2,98, +4,63
-2,82, +5,31
Variation in FR from AMP 300 ohm in band 100 Hz to 10 kHz, dB
-3,00, +4,70
-2,78, +5,32

Deviation of frequency response of Philips SHB 9100 headphone when connected to amplifiers with constant output impedance


Graphics setting view
Stands:
Range, dB:
Channel:




Table of measured characteristics
Variation in frequency response with amplifiers with constant output resistance from Philips SHB 9100
Channel
Center/Summary
With amplifier impedance at 10 ohm in band 20 Hz to 20 kHz, dB
0,2
With amplifier impedance at 20 ohm in band 20 Hz to 20 kHz, dB
0,4
With amplifier impedance at 50 ohm in band 20 Hz to 20 kHz, dB
0,7
With amplifier impedance at 100 ohm in band 20 Hz to 20 kHz, dB
0,8
With amplifier impedance at 300 ohm in band 20 Hz to 20 kHz, dB
1,0

*Center channel is received by data averaging between the left and right channels


Frequency response of Philips SHB 9100 headphone when connected to an amplifier with zero output impedance and raising of output impedanse in low frequencies


Graphics setting view
Stands:
Range, dB:
Channel:




Table of measured characteristics
Frequency response with an amplifier with zero output resistance and raising of output resistance in low frequencies from Philips SHB 9100
Channel
Left
Right
Variation in frequency response in band from 100 Hz to 10 kHz, dB
-4,64, 6,81
-4,08, 5,63

Deviation of frequency response of Philips SHB 9100 headphone when connected to an amplifier with zero output impedance and raising of output impedanse in low frequencies


Graphics setting view
Stands:
Range, dB:
Channel:




Table of measured characteristics
Variance of frequency response Philips SHB 9100 depending on the total output resistance of the amplifier with zero resistance and a rise of resistance at low frequencies
Variance frequency response at the frequency 20 Hz, dB
-4,8
Variance frequency response at the frequency 20 Hz, dB
-4,8
Variance frequency response at the frequency 40 Hz, dB
-1,9
Variance frequency response at the frequency 40 Hz, dB
-1,9
Variance frequency response at the frequency 80 Hz, dB
-0,7
Variance frequency response at the frequency 80 Hz, dB
-0,7

Perception of headphone frequency response curves of equal loudness ISO 226-2009 of Philips SHB 9100 headphone


Graphics setting view
Stands:
Channel:




Table of measured characteristics
Perception of headphone frequency response curves of equal loudness ISO 226-2009 from Philips SHB 9100
Channel
Center/Summary
From level 48 dB at 72 dB SPL in band 100 Hz to 10 kHz, dB
-6,1, +14,4
From level 36 dB at 72 dB SPL in band 100 Hz to 10 kHz, dB
-5,0, +11,4
From level 24 dB at 72 dB SPL in band 100 Hz to 10 kHz, dB
-4,0, +8,3
From level 12 dB at 72 dB SPL in band 100 Hz to 10 kHz, dB
-2,9, +5,2
From level 0 dB at 72 dB SPL in band 100 Hz to 10 kHz, dB
-2,6, +4,3
From level -12 dB at 72 dB SPL in band 100 Hz to 10 kHz, dB
-2,7, +5,5
From level -24 dB at 72 dB SPL in band 100 Hz to 10 kHz, dB
-3,8, +6,6
From level -36 dB at 72 dB SPL in band 100 Hz to 10 kHz, dB
-6,4, +7,6

*Center channel is received by data averaging between the left and right channels

Table's data are based on the results from the test stand HDM1



On-line comparison and selection services for Philips SHB 9100

Compare the sensitivity and impedance Philips SHB 9100 versus other models.

The automatic selection of the optimal AMP models from Philips SHB 9100 from the measured power parameters of the amplifying part and the measured parameters of the headphones for different purpose of use.

Close

Measurements of Philips SHB 9100 were carried out by Roman Kuznetsov on the hardware-software complex RAA.

The Philips SHB 9100 test was conducted as a black box test, without regard to cost and prestige. This is the basic principle for making measurements, measurement reports and developing tests in RAA.



Kuznetsov Roman
Founder of RAA



Known by the nickname romanrex
Аuthor of articles iXBT.com




Philips SHB 9100 is available in reports and services. You are in a professional report.

Service and suite of tests

Information for all

Comparison of on-line graphs

Information for professionals

report for a pro

Comparison of on-line graphs






Original text in Russian page. Translation page is not yet ready

You can help with translation via the: forum, facebook and feedback.


Comments

No comments to Philips SHB 9100
Commentary view:





Want to leave a comment or ask a question? Register now or log in