You can view the test results on the comparison pages and summary reports for beginners and professionals. You can go to the desired report or comparison/selection service through the menu on this page. Additionally, you can go to the comparison pages from any graph in this report and add other tested products for direct comparison.



This is a summary report of headphones for professionals.

You can additionally look for AKG K 702






Sensitivity average in band from 100 Hz - 10 kHz103.6dB/V SPL
91.6dB/mW SPL
Impedance average in band from 40 Hz - 15 kHz63.6ohm
For 90 dB SPL, a voltage is required-13.6dBV
0.209VRMS
Taking into account the peak factor of 9 dB for the music signal-4.6 dBV
0.588VRMS
Measurements were performed on the stand:HDM1


Frequency response AKG K 702 headphone

АЧХ - Стенд: HDM1

Your browser does not support Canvas
Graphics setting view
Channel

Range

Smoothing


Brief information

Clicking on the graph will take you to the comparison page of different models with advanced graph display settings.



Impedance / Electric phase AKG K 702 headphone

Your browser does not support Canvas
Graphics setting view
Channel


Channel:LeftRight
Impedance average in band from 40 Hz - 15 kHz63.6 63.6ohm
Resistance at 1 kHz59.4 59.4ohm
Resistance at 500 Hz60.8 60.8ohm
The minimum value in band from 40 Hz - 15 kHz59.3 59.3ohm
The maximum value in band from 40 Hz - 15 kHz82.4 82.4ohm


Your browser does not support Canvas
Graphics setting view
Channel

Range


Channel:LeftRight
Phase deviation is the average in the range 40 Hz - 15 kHz6.8 6.8°
Phase at 1 kHz1.6 1.6°
Phase at 500 Hz-1.2 -1.2°
The minimum value in band from 40 Hz - 15 kHz-2.1 -2.1°
The maximum value in band from 40 Hz - 15 kHz36.1 36.1°



Brief information

Clicking on the graph will take you to the comparison page of different models with advanced graph display settings.



Frequency response and sensitivity AKG K 702 headphone

Your browser does not support Canvas
Graphics setting view
Channel

Smoothing


Channel:LeftRight
Sensitivity average in band from 100 Hz - 10 kHz103.0 104.1dB/V SPL
Sensitivity average in band from 100 Hz - 10 kHz91.192.2 dB/mW SPL
Sensitivity at 1 kHz101.5102.0dB/V SPL
Sensitivity at 500 Hz101.1101.5dB/V SPL


Your browser does not support Canvas
Graphics setting view
Type of chart

SPL


SPLVoltageCurrentPower
dB SPLdBVVRMSdB(mA)mAdBmmW
60-43.60.007-19.70.10-31.60.001
70-33.60.021-9.70.33-21.60.007
80-23.60.0660.311.0-11.60.068
90-13.60.2110.33.3-1.60.68
100-3.60.6620.310.48.46.8
1106.42.130.332.818.468.4
12016.46.640.310428.4684
13026.420.950.332838.46841



Brief information

Clicking on the graph will take you to the comparison page of different models with advanced graph display settings.



Other summary reports for AKG K 702 headphone

report for a newbie

Your browser does not support CanvasA simple report for beginners with explanations of the main characteristics.

Compatibility with amplifier sources

Your browser does not support CanvasA report evaluating the compatibility of AKG K 702 with various amplifier sources.

Target curves and equalization

Your browser does not support CanvasA report with an assessment of compliance with target curves and recommended settings for AKG K 702 equalization



More detailed

Measurements of AKG K 702 were carried out by Roman Kuznetsov on the hardware-software complex RAA.

The AKG K 702 test was conducted as a black box test, without regard to cost and prestige. This is the basic principle for making measurements, measurement reports and developing tests in RAA.

I believe that it is important to do not make an absolute assessment of the device, but an aggregate assessment when working together with a source amplifier and taking into account external factors. This allows you to effectively reveal the potential of the entire set of devices or to make a more optimal choice of components.




Kuznetsov Roman
Founder of RAA



Known by the nickname romanrex
Аuthor of articles iXBT.com



Information for Authors. You can freely use the graphics in your articles with a link to us.












Original text in Russian page. Translation page is not yet ready

You can help with translation via the: facebook and feedback.




Comments

Commentary view:





Alan
Изображения, медиа и смайлы доступны в исходном чате.
2020-06-16 15:20:12

Комментарий к оглавлению отчетов AKG K 702
Здравствуйте Роман.
Производители указывают максимальную мощность 200мв. вы "Для шумной обстановки желателен усилитель с уровнем напряжения не менее 18.40 dBV на нагрузке 63.50 Ом и 130.94 мА для шумной" (что равно 1000мв)
Можете объяснить?
Reply


romanrex
Изображения, медиа и смайлы доступны в исходном чате.
2020-06-21 00:28:07

Комментарий к оглавлению отчетов AKG K 702

Alan 2020-06-16 15:20:12
Комментарий к оглавлению отчетов AKG K 702
Здравствуйте Роман.
Производители указывают максимальную мощность 200мв. вы "Для шумной обстановки желателен усилитель с уровнем напряжения не менее 18.40 dBV на нагрузке 63.50 Ом и 130.94 мА для шумной" (что равно 1000мв)
Можете объяснить?



200 мВт при 63.5 Ом - это 3.56 В на 56 мА. Это справедливо для одиночного синуса. Если вместо синуса у нас с той же амплитудой по напряжению будет меандр, то амплитуда по напряжению останется той же, а вот тока будет расходоваться на 3 дБ больше. Музыкальный же сигнал наоборот менее плотный, где-то от -15 до -21 дБ по сравнению с меандром. Соответственно, при амплитуде 3.56 В в среднем будет расходоваться ток на 12~18 дБ меньше чем при синусе и это будет равно 14~7 мА, а реальная мощность будет равна 49.84~25 мВт.

Т.е. при оценке максимальной мощности надо знать в каком качестве эта мощность указана. Выражает уровень напряжения, при превышении которого будут расти искажения, или наоборот перегрев катушки, что зависит от величины тока?


Например, для музыкального сигнала в 200 мВ при плотности -15 дБ амплитуда по напряжению и силы тока будут считаться так:
200 мВт = -6.9 dBW. Поправка плотности тока прибавляется как половинчатое значение +6 дБ от 12 дБ. Получаем -0.9 dBW. Это 17.1 dBV (7.1 В) и 41 дБ(мА) или 113 мА. Из тока вычитаем поправку в 12 дБ и получаем 29 дБ(мА) = 28.1 мА

Т.е. искомая мощность получается 7.1 В * 28.1 мА = 200 мВт

Если применить другую поправку на плотность музыкального сигнала, то значения будут получаться другими. Какие поправки заложил конкретный производитель, обычно неизвестно.


В рекомендациях значения рассчитываются без учета рекомендуемой максимальной мощности от производителей, и эти значения выражаются не через мощность, а отдельно напряжение и ток, где напряжение учитывает неравномерность по громкости музыкального сигнала, а ток - его плотность.