A suite of tests for a headphone amplifier can be applied to just a universal output without a formal presence of an amplifier, if in this mode you can connect headphones to this output. Based on the results of the tests, you can understand the real picture, is the output powerful enough or not, with the initial data on the circuitry as a "black box".

Line-out, differences from the output for headphones and speakers

Advantages and disadvantages of balanced amplifiers

Test report - general data Erzetich Bacillus Tilia (as headphone amplifier)

Frequency response, Impedance and Frequency response with standard headphones

Your browser does not support Canvas

Voltage levels from the load at the output of the amplifier

Your browser does not support Canvas

Average value of impedance band in 40 Hz - 15 kHz57.4ohm
Voltage:
Linear Mode / Maximum or before clipping level
17.1/18.1dBV
7.2/8.0VRMS
Current:
Linear Mode / Maximum or before clipping level
23.6/38.1dB(mA)
15.1/79.9mA





Brief information

Clicking on the graph will take you to the comparison page of different models with advanced graph display settings.





Frequency response Erzetich Bacillus Tilia (as headphone amplifier)

Your browser does not support Canvas
Graphics setting view
Channel

Range

Channel:LeftRight
Variation in frequency response in band from 40 Hz - 15 kHz -0.0, +0.0-0.0, +0.0dB



Brief information

Clicking on the graph will take you to the comparison page of different models with advanced graph display settings.

On the frequency response comparison page, there is an export option and additional tools for adjusting the frequency response



Impedance Erzetich Bacillus Tilia (as headphone amplifier)

Your browser does not support Canvas
Graphics setting view
Channel

Channel:LeftRight
Impedance average in band from 40 Hz - 15 kHz57.5 57.3ohm
The minimum value in band from 40 Hz - 15 kHz57.5 57.3ohm
The maximum value in band from 40 Hz - 15 kHz57.5 57.3ohm


Comparison of basic characteristics AMPs


Brief information

Clicking on the graph will take you to the comparison page of different models with advanced graph display settings.



Frequency response Erzetich Bacillus Tilia with resistive load

Your browser does not support Canvas
Graphics setting view
Channel

Range

Frequency response of amplifier with resistive load @ 40 Hz - 15 kHz
Channel:LeftRight
TEST 16 ? + Erzetich Bacillus Tilia 0.00.0dB
TEST 32 ? + Erzetich Bacillus Tilia 0.00.0dB
TEST 64 ? + Erzetich Bacillus Tilia 0.00.0dB
TEST 126 ? + Erzetich Bacillus Tilia 0.00.0dB
TEST 256 ? + Erzetich Bacillus Tilia 0.00.0dB
TEST 512 ? + Erzetich Bacillus Tilia 0.00.0dB



Brief information

Clicking on the graph will take you to the comparison page of different models with advanced graph display settings.

On the frequency response comparison page, there is an export option and additional tools for adjusting the frequency response



Frequency response Erzetich Bacillus Tilia loaded dynamic headphone type

Your browser does not support Canvas
Graphics setting view
Channel

Range

Frequency response of amplifier loaded dynamic headphone type @ 40 Hz - 15 kHz
Channel:LeftRight
TEST 10000 ? + Erzetich Bacillus Tilia 0.00.0dB
Grado GH4 Limited Edition + Erzetich Bacillus Tilia 5.65.2dB



Brief information

Clicking on the graph will take you to the comparison page of different models with advanced graph display settings.

On the frequency response comparison page, there is an export option and additional tools for adjusting the frequency response



Frequency response Erzetich Bacillus Tilia loaded type balance armature headphone type

Your browser does not support Canvas
Graphics setting view
Channel

Range

Frequency response of amplifier loaded type balance armature headphone type @ 40 Hz - 15 kHz
Channel:LeftRight
TEST 10000 ? + Erzetich Bacillus Tilia 0.00.0dB
Campfire Audio Andromeda + Erzetich Bacillus Tilia 14.214.3dB
Fearless Audio S8F Freedom + Erzetich Bacillus Tilia 10.910.1dB



Brief information

Clicking on the graph will take you to the comparison page of different models with advanced graph display settings.

On the frequency response comparison page, there is an export option and additional tools for adjusting the frequency response



THD vs load vs output voltage Erzetich Bacillus Tilia

Your browser does not support Canvas
Graphics setting view
Channel

Load

Harmonic, number

Your browser does not support Canvas
Graphics setting view
Channel

Load

Harmonic, number

Your browser does not support Canvas
Graphics setting view
Channel

Load


Brief information

Clicking on the graph will take you to the comparison page of different models with advanced graph display settings.



Maximum voltage output level vs load Erzetich Bacillus Tilia

Your browser does not support Canvas
Graphics setting view
Type of chart

RAW coordinates

Power characteristics of the Voltage Current
dBVVRMSdB(mA)mA
Equivalent class A 17.17.223.615.1
Equivalent class AB 17.17.237.071.2
Equivalent class B 17.17.237.071.2
Maximum mode 18.18.038.179.9


Volume Control TypeAnalog
Optimal range of volume control56.0dB


Comparison Erzetich Bacillus Tilia and another amplifiers by loudness (Volume Level)

Main characteristics of the Erzetich Bacillus Tilia


Brief information

Clicking on the graph will take you to the comparison page of different models with advanced graph display settings.



Maximum voltage output level vs load Erzetich Bacillus Tilia

Your browser does not support Canvas
Graphics setting view
Type of chart

RAW coordinates

Maximum Amplifier Voltage Level
Load Pure or equal class AOptimal or equal class ABHard or equal class BMax, before clipping
dBVVRMSdBVVRMSdBVVRMSdBVVRMS
15.8 ohm -13.00.21.00.21.00.22.00.2
24.5 ohm -9.80.34.20.34.20.35.20.3
30.5 ohm -5.40.55.60.55.60.56.60.5
62.4 ohm -1.00.910.00.910.00.911.00.9
100 ohm 4.21.612.21.612.21.613.21.6
198.9 ohm 14.55.314.55.314.55.315.55.3
300 ohm 16.56.615.56.615.56.616.56.6
763 ohm 16.46.616.46.616.46.617.46.6
Not loaded17.17.217.17.217.17.218.17.2



Maximum level of amplifier current
Load Pure or equal class AOptimal or equal class ABHard or equal class BMax, before clipping
dB(mA)mAdB(mA)mAdB(mA)mAdB(mA)mA
15.8 ohm 23.114.237.071.237.071.238.179.9
24.5 ohm 22.413.236.466.136.466.137.474.2
30.5 ohm 25.017.735.962.735.962.736.970.4
62.4 ohm 23.114.234.050.434.050.435.056.5
100 ohm 24.216.332.240.832.240.833.245.8
198.9 ohm 28.526.528.526.528.526.529.529.8
300 ohm 26.922.225.919.725.919.726.922.2
763 ohm 18.78.718.78.718.78.719.79.7


Power
Load Pure or equal class AOptimal or equal class ABHard or equal class BMax, before clipping
dBmmWdBmmWdBmmWdBmmW
15.8 ohm 5.13.219.080.119.080.120.0100.9
24.5 ohm 6.34.320.3107.220.3107.221.3134.9
30.5 ohm 9.89.520.8120.020.8120.021.8151.1
62.4 ohm 11.012.622.0158.522.0158.523.0199.5
100 ohm 14.226.522.2166.522.2166.523.2209.8
198.9 ohm 21.5140.121.5140.121.5140.122.5176.4
300 ohm 21.7147.220.7117.020.7117.021.7147.2
763 ohm 17.657.217.657.217.657.218.672.0



Brief information

Clicking on the graph will take you to the comparison page of different models with advanced graph display settings.



   

Spectrum of Total Harmonic Distortion vs Level Erzetich Bacillus Tilia (as headphone amplifier)

Your browser does not support Canvas
Graphics setting view
Channel

Level

Range

Your browser does not support Canvas
Graphics setting view
Channel

Level

Range

Your browser does not support Canvas
Graphics setting view
Channel

Shift

dBm

Range

Your browser does not support Canvas
Graphics setting view
Channel

Shift

dBV

Range




Brief information

Clicking on the graph will take you to the comparison page of different models with advanced graph display settings.





More detailed

Measurements of Erzetich Bacillus Tilia were carried out by Roman Kuznetsov on the hardware-software complex RAA.

The Erzetich Bacillus Tilia test was conducted as a black box test, without regard to cost and prestige. This is the basic principle for making measurements, measurement reports and developing tests in RAA.

I believe that it is important to do not make an absolute assessment of the device, but an aggregate assessment when working together with a headphones and taking into account external factors. This allows you to effectively reveal the potential of the entire set of devices or to make a more optimal choice of components.




Kuznetsov Roman
Founder of RAA



Known by the nickname romanrex
Аuthor of articles iXBT.com



Information for Authors. You can freely use the graphics in your articles with a link to us.












Original text in Russian page. Translation page is not yet ready

You can help with translation via the: facebook and feedback.




Comments

No comments to Erzetich Bacillus Tilia
Commentary view:





Want to leave a comment or ask a question? Register now or log in