After testing in the benchmark mode in the Reference Audio Analyzer software, the data is added to the online database of the RAA website.
You can view the test results on the comparison pages
and summary reports for beginners
and professionals
. You can go to the desired report or comparison/selection service through the menu on this page. Additionally, you can go to the comparison pages from any graph in this report and add other tested products for direct comparison.
This is a summary report of headphones for professionals.
You can additionally look for FATFreq Gr. Maestro 1
You can view the test results on the comparison pages



This is a summary report of headphones for professionals.
You can additionally look for FATFreq Gr. Maestro 1
- Simple report for dummies with explanations of the main characteristics
- Compatibility with amplifier sources
- Recommendations for equalization and comparison with target curves

Sensitivity average in band from![]() | 114.5 | dB/V SPL |
98.7 | dB/mW SPL | |
Impedance average in band from 40 Hz - 15 kHz | 25.8 | ohm |
For 90 dB SPL, a voltage is required | -24.5 | dBV |
0.059 | VRMS | |
Taking into account the peak factor of 9 dB for the music signal | -15.5 | dBV |
0.167 | VRMS | |
Measurements were performed on the stands: | SIEC![]() ![]() |
С 2024 года измерения полноразмерных наушников в RAA проводятся не только на инструментальных стендах, но и вживую с помощью разработанной системы в RAA - Live Measurement System. Это позволяет увидеть реальное поведение наушников и их вариативность звучания относительно стандартных стендов. Результаты таких измерений в отчетах обозначаются как со стендов Human. В этом отчете - это:
Т.к. АЧХ зависит от посадки наушников и их прогрева/износа, то в RAA была разработан универсальный комплект Live Measurement System


Brief information
Clicking on the graph will take you to the comparison page of different models with advanced graph display settings.
Graphics setting view
Channel Range
Frequency band
Channel: | Left | Right | |
Phase deviation is the average in the range 40 Hz - 15 kHz | -18.2 | -20.3 | ° |
Phase at 1 kHz | -26.2 | -29.0 | ° |
Phase at 500 Hz | -27.6 | -29.8 | ° |
The minimum value in band from 40 Hz - 15 kHz | -28.3 | -30.8 | ° |
The maximum value in band from 40 Hz - 15 kHz | -3.8 | -4.0 | ° |
Brief information
Clicking on the graph will take you to the comparison page of different models with advanced graph display settings.
Graphics setting view
Type of chart SPL
SPL | Voltage | Current | Power | |||
dB SPL | dBV | VRMS | dB(mA) | mA | dBm | mW |
60 | -54.5 | 0.002 | -22.8 | 0.073 | -38.7 | 0.000 |
70 | -44.5 | 0.006 | -12.8 | 0.23 | -28.7 | 0.001 |
80 | -34.5 | 0.019 | -2.8 | 0.73 | -18.7 | 0.014 |
90 | -24.5 | 0.059 | 7.2 | 2.3 | -8.7 | 0.14 |
100 | -14.5 | 0.19 | 17.2 | 7.3 | 1.3 | 1.4 |
110 | -4.5 | 0.59 | 27.2 | 23.0 | 11.3 | 13.6 |
120 | 5.5 | 1.9 | 37.2 | 72.7 | 21.3 | 136 |
130 | 15.5 | 5.9 | 47.2 | 230 | 31.3 | 1364 |
Brief information
Clicking on the graph will take you to the comparison page of different models with advanced graph display settings.