Measurement's report iBasso D12 Anaconda - Reference Audio Analyzer

iBasso D12 Anaconda

About this report
This is a report for professionals with a suite of test of headphone amplifier.
You can see a simple report for "dummies" with explanations of the main characteristics for iBasso D12 Anaconda

A suite of tests for a headphone amplifier can be applied to just a universal output without a formal presence of an amplifier, if in this mode you can connect headphones to this output. Based on the results of the tests, you can understand the real picture, is the output powerful enough or not, with the initial data on the circuitry as a "black box".

Line-out, differences from the output for headphones and speakers

Advantages and disadvantages of balanced amplifiers

Test report - general data iBasso D12 Anaconda (as headphone amplifier)

Frequency response, Impedance and Frequency response with standard headphones

Your browser does not support Canvas

Average value of impedance band in 40 Hz - 15 kHz5.3ohm





Brief information

Clicking on the graph will take you to the comparison page of different models with advanced graph display settings.





Frequency response iBasso D12 Anaconda (as headphone amplifier)

Your browser does not support Canvas
Graphics setting view
Channel

Range

Channel:LeftRight
Variation in frequency response in band from 40 Hz - 15 kHz -3.7, +3.2-3.7, +3.2dB



Brief information

Clicking on the graph will take you to the comparison page of different models with advanced graph display settings.

On the frequency response comparison page, there is an export option and additional tools for adjusting the frequency response



Impedance iBasso D12 Anaconda (as headphone amplifier)

Your browser does not support Canvas
Graphics setting view
Channel

Channel:LeftRight
Impedance average in band from 40 Hz - 15 kHz5.3 5.3ohm
The minimum value in band from 40 Hz - 15 kHz3.6 3.6ohm
The maximum value in band from 40 Hz - 15 kHz8.3 8.3ohm


Comparison of basic characteristics AMPs


Brief information

Clicking on the graph will take you to the comparison page of different models with advanced graph display settings.



Frequency response iBasso D12 Anaconda with resistive load

Your browser does not support Canvas
Graphics setting view
Channel

Range

Frequency response of amplifier with resistive load @ 40 Hz - 15 kHz
Channel:LeftRight
TEST 16 ? + iBasso D12 Anaconda 1.01.0dB
TEST 32 ? + iBasso D12 Anaconda 0.50.5dB
TEST 64 ? + iBasso D12 Anaconda 0.30.3dB
TEST 126 ? + iBasso D12 Anaconda 0.10.1dB
TEST 256 ? + iBasso D12 Anaconda 0.10.1dB
TEST 512 ? + iBasso D12 Anaconda 0.00.0dB



Brief information

Clicking on the graph will take you to the comparison page of different models with advanced graph display settings.

On the frequency response comparison page, there is an export option and additional tools for adjusting the frequency response



Frequency response iBasso D12 Anaconda loaded dynamic headphone type

Your browser does not support Canvas
Graphics setting view
Channel

Range

Frequency response of amplifier loaded dynamic headphone type @ 40 Hz - 15 kHz
Channel:LeftRight
TEST 10000 ? + iBasso D12 Anaconda 0.00.0dB
Grado GH4 Limited Edition + iBasso D12 Anaconda 0.50.6dB



Brief information

Clicking on the graph will take you to the comparison page of different models with advanced graph display settings.

On the frequency response comparison page, there is an export option and additional tools for adjusting the frequency response



Frequency response iBasso D12 Anaconda loaded type balance armature headphone type

Your browser does not support Canvas
Graphics setting view
Channel

Range

Frequency response of amplifier loaded type balance armature headphone type @ 40 Hz - 15 kHz
Channel:LeftRight
TEST 10000 ? + iBasso D12 Anaconda 0.00.0dB
Campfire Audio Andromeda + iBasso D12 Anaconda 6.56.4dB
Fearless Audio S8F Freedom + iBasso D12 Anaconda 3.63.6dB



Brief information

Clicking on the graph will take you to the comparison page of different models with advanced graph display settings.

On the frequency response comparison page, there is an export option and additional tools for adjusting the frequency response





More detailed

Measurements of iBasso D12 Anaconda were carried out by Roman Kuznetsov on the hardware-software complex RAA.

The iBasso D12 Anaconda test was conducted as a black box test, without regard to cost and prestige. This is the basic principle for making measurements, measurement reports and developing tests in RAA.

I believe that it is important to do not make an absolute assessment of the device, but an aggregate assessment when working together with a headphones and taking into account external factors. This allows you to effectively reveal the potential of the entire set of devices or to make a more optimal choice of components.




Kuznetsov Roman
Founder of RAA



Known by the nickname romanrex
Аuthor of articles iXBT.com



Information for Authors. You can freely use the graphics in your articles with a link to us.




iBasso D12 Anaconda is available in reports and services. You are in a professional report.

Information for entry level users










Original text in Russian page. Translation page is not yet ready

You can help with translation via the: facebook and feedback.




Comments

No comments to iBasso D12 Anaconda
Commentary view:





Want to leave a comment or ask a question? Register now or log in