After testing in the benchmark mode in the Reference Audio Analyzer software, the data is added to the online database of the RAA website.
You can view the test results on the comparison pages
and summary reports for beginners
and professionals
. You can go to the desired report or comparison/selection service through the menu on this page. Additionally, you can go to the comparison pages from any graph in this report and add other tested products for direct comparison.
This is a report on compliance with target frequency response curves with recommended equalizer settings for Cozoy D1.
You can additionally look for Cozoy D1
You can view the test results on the comparison pages
This is a report on compliance with target frequency response curves with recommended equalizer settings for Cozoy D1.
You can additionally look for Cozoy D1
- Simple report for dummies with explanations of the main characteristics
- Main professional characteristics report
- Compatibility with amplifier sources

С 2024 года измерения полноразмерных наушников в RAA проводятся не только на инструментальных стендах, но и вживую с помощью разработанной системы в RAA - Live Measurement System. Это позволяет увидеть реальное поведение наушников и их вариативность звучания относительно стандартных стендов. Результаты таких измерений в отчетах обозначаются как со стендов Human. В этом отчете - это:
Т.к. АЧХ зависит от посадки наушников и их прогрева/износа, то в RAA была разработан универсальный комплект Live Measurement System
Stand: SIEC
Stand: IEC711 Coupler
Stand: type 4.3 artificial ear - exprimental
Brief information
Clicking on the graph will take you to the comparison page of different models with advanced graph display settings.
Стенд: SIEC
| Name | Deviation of frequency response |
| Simgot EA500LM Black | 0.57 |
| EPZ Q1 Pro | 0.58 |
| Kefine Klanar | 0.61 |
| KZ Castor Harman Edition (Silver) 1000 | 0.65 |
| KZ ZS10 Pro X | 0.66 |
| TRN Conch Reference | 0.70 |
Выборка из 1124 протестированных моделей через стенд SIEC.
Стенд: IEC711 Coupler
| Name | Deviation of frequency response |
| Kefine Klanar | 0.58 |
| TRUTHEAR NOVA | 0.58 |
| EPZ Q1 Pro | 0.61 |
| Simgot EA500LM Black | 0.69 |
| KZ ZS10 Pro X | 0.71 |
| Moondrop Solis II | 0.72 |
Выборка из 261 протестированных моделей через стенд IEC711 Coupler.
Стенд: type 4.3 artificial ear - exprimental
| Name | Deviation of frequency response |
| KZ ZS10 Pro X | 0.74 |
| Simgot EA500LM Black | 0.88 |
| KZ Castor Harman Edition (Silver) 1000 | 0.89 |
| Fosi Audio IM4 Black | 0.92 |
| Fosi Audio K7 Balanced Out | 0.93 |
| Fosi Audio IM4 Gold | 0.93 |
Выборка из 145 протестированных моделей через стенд type 4.3 artificial ear - exprimental.
Brief information
Clicking on the graph will take you to the comparison page of different models with advanced graph display settings.
More detailed
Measurements of Cozoy D1 were carried out by Roman Kuznetsov on the hardware-software complex RAA.
The Cozoy D1 test was conducted as a black box test, without regard to cost and prestige. This is the basic principle for making measurements, measurement reports and developing tests in RAA.
I believe that it is important to do not make an absolute assessment of the device, but an aggregate assessment when working together with a source amplifier and taking into account external factors. This allows you to effectively reveal the potential of the entire set of devices or to make a more optimal choice of components.
Kuznetsov Roman
Founder of RAA
Information for Authors. You can freely use the graphics in your articles with a link to us.
Original text in Russian page. Translation page is not yet ready
You can help with translation via the: facebook and feedback.